Table 2

Literature review of sentinel node detection in cervical cancers (Only Studies with more than 20 patients were presented)

Author
Yıl
Detection method
Tracer
Surgery
No. of cases
Lymph node dissection
Detection rate (%)
Positive SN
False negative SN
NPV (%)
Ultrastaging

Malur [44]
2001
ILS or BD
Albumin-RES
LT/LS
50
PN+PAN
80
6
1
97
(-)
Rhim [34]
2002
ILS + BD
Colloid albumin
LT
26
PN+PAN
100
5
1
95
(-)
Levenback [36]
2002
ILS + BD
Radiocolloid
LT
39
PN+PAN
100
8
1
97
(+)
Plante [2]
2003
BD
Antimony trisulfide colloid
LS
41
PN+PAN
79
12
0
100
(+)
Martinez-Palones [37]
2004
ILS + BD
Colloid albumin
LT/LS
25
PN+PAN
92
4
0
100
(+)
Chung [48]
2003
ILS + BD
Sulphur colloid
LT
26
PN+PAN(bifurcation)
100
1
0
100
?
Buist [49]
2003
ILS + BD
Colloid albumin
LS
25
PN
100
9
1
94
(+)
Hubalewska [50]
2003
ILS + BD
Nanocolloid
LT
37
PN+PAN
100
5
?
?
?
Van Dam [51]
2003
ILS
Nanocolloid
LS
25
PN
84
5
0
100
?
Marchiole [53]
2004
BD
-
LS
29
PN
100
2
3
87.5
(+)
Niikura [54]
2004
ILS + BD
Phytate
LT
20
PN
90
2
0
100
(+)
Pijpers [55]
2004
ILS + BD
Colloid albumin
LS
34
PN
97
17
1
92
?
Silva [42]
2005
ILS
Phytate
LT
56
PN
93
10
3
92
(+)
Rob [5]
2005
BD
-
LT/LS
100
PN+PAN
80
20
1
99
(+)
Di Stefano [56]
2005
BD
-
LT
50
PN
90
9
1
97
(+)
Angioli [57]
2005
ILS, (LS+BD)
Colloid albumin
LS
37 (83)
PN
70 (96.4)
9 (15)
0 (0)
100(100)
(+)
Lin [58]
2005
ILS
Sulfur colloid
LT
30
PN
100
7
0
100
(+)

BD: blue dye method, ILS: intraoperative lymphoscintigraphy, LS: laparoscopy, LT: laparotomy; NPV: negative predictive value, SN: sentinel node, (+): yes, (-):No, ?: Unknown, PN: Pelvic lymph node dissection, PAN: Para-aortic lymph node dissection

Ayhan et al. World Journal of Surgical Oncology 2008 6:53   doi:10.1186/1477-7819-6-53